    4.5 Ton 60,000 BTU 14 SEER Energy-Efficient Heat Pump - GSZ140601

    Standard Features Cabinet Features

    • High-efficiency scroll compressor
    • SmartShift® technology to ensure quiet reliable defrost
    • Factory-installed bi-flow liquid-line filter drier
    • Factory-installed suction-line accumulator
    • Factory-installed compressor crankcase heater
    • Factory-installed high-capacity muffler
    • High- and low-pressure switches
    • Service valves with sweat connections and easy access to gauge ports
    • Copper tube/enhanced aluminum fin coil
    • Fully charged for 15' of tubing length
    • Contactor with lug connection
    • Ground lug connection
    • AHRI Certified; ETL Listed

    Cabinet Features

    • Goodman® brand sound control top design
    • Steel louver coil guard
    • Heavy-gauge galvanized-steel cabinet
    • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
    • Top and side maintenance access
    • Service ports and controls are accessible while unit is operating
    • When properly anchored meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

    The art of precision

    Quiet Condenser Fan Motor - High-efficiency single-speed motor with special threeblade fan design provides dependable quiet airflow across condensing coil.

    Efficient Cooling Capacity - Refrigeration-grade premium copper tubing and aluminum fin condenser coil configuration deliver outstanding heat transfer properties with R-410A refrigerant.

    Goodman heat pumps simply work the way they are supposed to making each one a thing of beauty.

    Quiet Operation - An acoustically engineered top on the unit helps reduce noise levels compared to units without sound control enhancements.

    Factory-Installed Bi-flow Liquid Line Filter Drier - Protects the refrigerant system from dirt and moisture for longer service life compared to units without filter driers.

    Factory-Installed Heater Band and Suction Line Accumulator - Ensures refrigerant is ready even in extreme external temperatures for smooth and energy-efficient performance.

    For information regarding our return policy, please click here.


    Specifications

    General Characteristics

    Specification:
    Cooling (BTU/h)60,000
    Heating (BTU/h)60,000
    Decibels76
    Compressor RLA26.4
    Compressor LRA134.0
    Compressor TypeScroll
    Condenser Fan Motor Horsepower1/4
    Condenser Fan Motor FLA1.30

     

    Refrigeration System:
    Refrigerant Liquid Line Size *1 ("O.D.)3/8"
    Refrigerant Suction Line Size *1 ("O.D.)1 1/8"
    Refrigerant Connection Liquid Valve Size ("O.D.)3/8"
    Refrigerant ConnectionSuction Valve Size ("O.D.)7/8"
    Standard Line Set Length (max. feet)80
    Long Line Set Length (max. feet) ²
    Equivalent Length
    Linear Length
    Vertical Length (outdoor below indoor)
    Vertical Length (outdoor above indoor)

    250
    200
    80
    80
    Valve Connection TypeSweat
    Refrigerant Charge (oz.)205

     

    Electrical Data:
    Volts/Phase (60 Hz)208/230-1
    Minimum Circuit Ampacity *334.3
    Max. Overcurrent Protection *460
    Min/Max Volts197/253
    Electrical Conduit Size1/2" or 3/4"

     

    Weight:
    Equipment Weight277
    Shipping Weight292

    1. Tested and rated in accordance with ARI Standard 210/240
    2. Reference TP-107* for additional application requirements
    3. Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
    4. Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

    Notes:

    • Always check the S&R plate for electrical data on the unit being installed.
    • Installer will need to supply 7/8” to 1 1/8” adapters for suction line connections.
    • Unit is charged with refrigerant for 15’ of 3/8” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
    • Installation of these units may require the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
    Reviews