    Product Description

    Dow Froth Pak 650 Class A (E84) Spray Foam Kit

    Kit includes:

    • 1 Iso (A) cylinder 340317
    • 1 Polyol (B) cylinder 340320
    • GHA 15 (Gun Hose Assembly, 15' Hose) - 158398
      • 1 dispensing gun
      • 15 ft. hose
      • Assorted nozzles
        • 8 Cone white spray - 187918
        • 4 GG white spray - 187915
      • 1 wrench
      • 1 petroleum jelly packet
      • 1 instruction sheet

    Theoretical Field: 650 Board Feet.

    FROTH-PAK Foam Insulation is a closed cell, two-component, quick-cure polyurethane spray foam that fills cavities, penetrations, cracks and expansion joints. Unlike one-component foam, FROTH-PAK Foam Insulation is a chemically cured foam, significantly reducing curing time. FROTH-PAK™ Foam Insulation dispenses, expands and becomes tack-free in seconds. The product will skin over in 30–40 seconds and will be completely cured in minutes.*

    The Class-A rating (flame spread of 25 or less) of FROTH-PAK™ Foam Insulation allows its use in a wide range of interior and exterior industrial, commercial, institutional and residential settings. Check with local codes prior to use. If used in an exterior setting, a coating must be applied for ultraviolet (UV) protection.

    Physical Properties:

    FROTH-PAK™ Foam Insulation exhibits the typical properties and characteristics indicated in Table 2 when tested as represented.

    Fire Information:

    Cured FROTH-PAK™ foam is combustible and will burn if exposed to open flame or sparks from high-energy sources. Do not expose to temperatures above 240°F.

    Insulation:

    Complete operating instructions are provided with each FROTH-PAK™ Foam Insulation purchase. Read all information and cautions before application. Note: Avoid overfilling restricted spaces. Chemicals exert force during reaction, and expansion of foam may result in substrate deformation.

    *Actual cure time will depend on temperature, foam thickness, the specific nozzle used, etc.


    If you would like to add an optional 3M safety kit to your Froth Pak package, simply select Add 3M Safety Kit from the product options and then Add to Cart. Your selections will be reflected on the check out page.

    This 3M Safety Kit Includes:

    • 3M Disposable Protective Coverall Safety Work Wear
    • 3M Tekk Protection Nitrile Gloves
    • 3M Half Facepiece Disposable Respirator Assembly, Organic Vapor/Acid Gas Respiratory Protection , Large - 5303
    • 3M Safety Splash Goggle, Clear Anti Fog Lens - 334AF

    Specifications

    General Characteristics

    TYPICAL PHYSICAL PROPERTIES OF FROTH-PAK™ FOAM INSULATION

    These properties are typical but do not constitute specifications.

    Property and Test MethodValue*
    Flame Spread/Smoke Developed,(1), (2) ASTM E84/UL 723≤25 / ≤450
    Nominal Density, ASTM D1622, lb/ft&sup3:1.75
    Thermal Resistance(3) per inch, ASTM C518, ft2•h•°F/Btu, R-value, min.
    Initial
    Aged 180 days at 75°F – 1.0"
    Aged 180 days at 75°F – 2.0"

    6.6
    6.0(when sprayed as 1" thickness)
    12.2(6.1/in when sprayed as 2" thickness)
    Air Leakage,
    ASTM E283, cfm/ft2 @ 1.57 psf
    ASTM E2178, L/s/m2 @ 75 Pa

    0
    0
    Water Vapor Permeance, ASTM E96
    perm @ 1" thick
    perm @ 2" thick

    6.4
    3.2
    Water Absorption, ASTM D2842, % by volume3.2
    Dimensional Stability, ASTM D2126, % volume change
    100°F/97% RH @ 1 wk
    158°F/97% RH @ 1 wks
    -40°F/amb RH @ 1 wk
    158°F/amb RH @ 1 wks

    0.70
    8.3
    0.0
    3.1
    Compressive Strength, ASTM D1621, lb/in⊃, parallel17.2
    Tensile Strength, ASTM D1623, lb/in², parallel32.0
    Maximum Service Temperature, °F240

    (1) Tested at 2" thickness, full coverage.
    (2) This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.
    (3) R means resistance to heat flow. The higher the R-value, the greater the insulating power.

    Videos

    Reviews
    Product Question

    Product Questions

    Is this 650 board feet at 1" or 2" thick?
    14
    Is this open or closed cell foam insulation I need to insulate the floor above my crawl space and exterior walls of my basement and some roof area in my garage above my garage door where it is not insulated and dry walled we live in Denver Co which is a dryer climate So I'm wandering if this will be the proper foam to use.
    Thanks for your time!
    Mark
    11
    Is there a temperature range that I should be using this product with - a temperature too high or too low for the system to work properly.

    Tom
    4
    What is the r-value at 1 in
    3
    Could this foam be used on the interior cieling in my attic?
    3
    I'm wondering if this product could be used to fill the spaces inside the walls/ceiling of a 7'x7' plastic shed. There is a lot of free space inside these plastic walls and roof that would benefit from insulation for my cats. (Both Winter and Summer) I'm picturing shooting this foam into drilled holes at specific/recommended space intervals because of how fast it hardens. THanks for your feedback! Teresa
    3
    Will this work as a vapor barrior for a wine cellar at 1” depth. Also, how much sq foot does this kit translate to?
    2
    Will this product stick on stainless steel surface?
    1
    Can this be sprayed on a ceiling, I would like to insulate the floor of my utility room bathroom?
    0
    What is the recommended thickness for spraying an attic space?
    0
    Shipping Calculator